NPWJM 2016, 4(12): 127-132 Back to browse issues page
Electrocardiogram denoising in holter monitor devices using extended Kalman filter in disaster medicine field
Abstract:   (4081 Views)

Introduction: Measure, record and early detection of vital signs of War wounded as well as soldiers with injuries in war, camps and border areas where distances are far away of equipped centers hospital is necessity that can help to reduce casualties. This article examines the extended Kalman filter in eliminate movement and stress noises in ambulances holter monitor.

Methods: Using linearized form of Kalman filter in single channel electrocardiogram (ECG) denoising in holter monitor devices is main target of this article. In this article we using improved model of McSharry to generate synthetic ECG and SNR quantities and the improvement of this quantities to evaluate this article is being used.

Results: Using extended Kalman filter on channel 30 tested data shows improvement in SNR in terms of quantities in the range of 5 to 30 dB.

Conclusion: Research findings show that the Extended Kalman filter is stable due to a significant improvement in SNR quantities in ECG denoising. So  this filter can be used in holter monitoring devices in armed forces hospitals, and disaster medicine and ambulances also be used in times of disasters.

Keywords: Military medicine, Denoising, Electrocardiogram, Holter monitoring, Military Nursing
Full-Text [PDF 799 kb]   (3012 Downloads)    
Type of Study: Research | Subject: Special
Received: 2017/07/14 | Accepted: 2017/07/14 | Published: 2017/07/14
Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Electrocardiogram denoising in holter monitor devices using extended Kalman filter in disaster medicine field. NPWJM 2016; 4 (12) :127-132
URL: http://npwjm.ajaums.ac.ir/article-1-370-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 4, Issue 12 (12-2016) Back to browse issues page
پرستار و پزشک در رزم Nurse and Physician Within War
Persian site map - English site map - Created in 0.06 seconds with 35 queries by YEKTAWEB 4710